Physical Model of Electric Aging and Breakdown of Extruded Polymeric Insulated Power Cables
102
Citations
16
References
1982
Year
Materials ScienceElectric AgingElectrical EngineeringHigh Voltage CablesEngineeringVoltage BreakdownPhysical ModelThermal InsulationElectrical TransmissionTime-dependent Dielectric BreakdownElectronic PackagingElectrical PropertyPhysic Of FailureElectrical Insulation
This paper postulates a physical model of electric aging and breakdown of polymeric insulated high voltage cables and substantiates this model with results of tests. In accordance with the model, scission of molecular chains and formation of craters at discharging voids are responsible for the electric aging and voltage breakdown of polymeric insulation.