European Journal of Cardio-Thoracic Surgery · 2014 · 46 citations · 16 references
MedicineCardiologySurgeryCardiothoracic SurgeryInterventional CardiologySurgical InstrumentationCardiac Valve SurgerySurgical Valve ReplacementTranscatheter Aortic Valve ReplacementTranscatheter Valve TherapyCardiac Risk EvaluationHigh-risk Patient PopulationsHigh-risk Surgical PatientsPreoperative Cardiac EvaluationSelf-expanding StentsTransvalvular Pressure GradientValve Prosthesis Design
OBJECTIVES: The novel ACURATE TA™ transcatheter aortic valve (Symetis, Ecublens, Switzerland) is composed of a self-expanding nitinol stent covered by an anti-paravalvular leak skirt designed for transapical implantation. Since Conformite Europeenne (CE)-mark approval, the first 250 patients implanted with the newly approved device have been included in this post-market, multicentre registry. METHODS: The registry was conducted at 17 sites in Germany, Italy, Switzerland and Argentina to treat 250 high-risk elderly patients. This all-comers population presented preoperatively with a mean aortic gradient of 43.2 ± 17.4 mmHg, mean age of 80.9 ± 6.3 years, mean society of thoracic surgeons risk score of 8.0 ± 5.9% and mean logistic European System for Cardiac Operative Risk Evaluation (EuroSCORE) I of 22.3 ± 12.7%. The majority of patients (93%) were in New York Heart Association (NYHA) class III/IV. All patients were treated within a multidisciplinary Heart Team. RESULTS: The procedural success rate was 98% (n = 245) with two valve-in-valve procedures and three conversions to conventional surgery. The 30-day mortality rate was 6.8%. Postimplant echocardiography revealed a relevant paravalvular leak (moderate 2+) in 2.3% of patients, with all other patients demonstrating either none/trace or a 1+ leak. The 30-day stroke rate was 2.8% and the mean transvalvular gradient was 12.4 ± 5.8 mmHg. A new pacemaker implantation was required in 10.0% of patients and 85% of patients returning for the follow-up presented in NYHA class I/II. CONCLUSIONS: The short-term result of the registry shows a safety and efficacy profile comparable, if not improved in some aspects, with previously approved transcatheter aortic valve implantation devices. These 'real-world' data highlight an excellent functional outcome, especially in regard to a low rate of relevant paravalvular leak.
16
Two-Year Outcomes after Transcatheter or Surgical Aortic-Valve Replacement
Susheel Kodali, Mathew Williams, Craig R. Smith et al. · New England Journal of Medicine · 2012 · 2.3K citations · Full text
Medicine, Cardiology, Surgery +17
Registry of Transcatheter Aortic-Valve Implantation in High-Risk Patients
Martine Gilard, Hélène Eltchaninoff, Bernard Iung et al. · New England Journal of Medicine · 2012 · 1.2K citations · Full text
Medicine, Cardiology, Surgery +15
M.B. Leon, Nicolò Piazza, Eugenia Nikolsky et al. · European Heart Journal · 2011 · 1.2K citations · Full text