American Journal of Neuroradiology · 2012 · 57 citations · 29 references
MedicinePediatricsRadiologyDiagnostic ImagingDiagnostic RadiologyPediatric RadiologyComputed TomographyComputed Tomography PhysicsHead ImagingImage Quality AssessmentPediatric ImagingPediatric NeuroradiologyFeasibility Study DesignIterative Dose Reduction AlgorithmsIterative Image ReconstructionIterative ReconstructionPediatric Computed Tomography Dose ManagementPediatric Head ImagingRadiation Dose Reduction
BACKGROUND AND PURPOSE: Iterative reconstruction techniques facilitate CT dose reduction; though to our knowledge, no group has explored using iterative reconstruction with pediatric head CT. Our purpose was to perform a feasibility study to assess the use of ASIR in a small group of pediatric patients undergoing head CT. MATERIALS AND METHODS: An Alderson-Rando head phantom was scanned at decreasing 10% mA intervals relative to our standard protocol, and each study was then reconstructed at 10% ASIR intervals. An intracranial region of interest was consistently placed to estimate noise. Our ventriculoperitoneal shunt CT protocol was subsequently modified, and patients were scanned at 20% ASIR with approximately 20% mA reductions. ASIR studies were anonymously compared with older non-ASIR studies from the same patients by 2 attending pediatric neuroradiologists for diagnostic utility, sharpness, noise, and artifacts. RESULTS: The phantom study demonstrated similar noise at 100% mA/0% ASIR (3.9) and 80% mA/20% ASIR (3.7). Twelve pediatric patients were scanned at reduced dose at 20% ASIR. The average CTDI(vol) and DLP values of the 20% ASIR studies were 22.4 mGy and 338.4 mGy-cm, and for the non-ASIR studies, they were 28.8 mGy and 444.5 mGy-cm, representing statistically significant decreases in the CTDI(vol) (22.1%, P = .00007) and DLP (23.9%, P = .0005) values. There were no significant differences between the ASIR studies and non-ASIR studies with respect to diagnostic acceptability, sharpness, noise, or artifacts. CONCLUSIONS: Our findings suggest that 20% ASIR can provide approximately 22% dose reduction in pediatric head CT without affecting image quality.
29
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
David J. Brenner, Carl D. Elliston, Eric J. Hall et al. · American Journal of Roentgenology · 2001 · 3.2K citations
Medicine, Pediatrics, Radiology +17
MEDICAL RADIATION EXPOSURE IN THE U.S. IN 2006: PRELIMINARY RESULTS
Fred A. Mettler, Bruce Thomadsen, Mythreyi Bhargavan et al. · Health Physics · 2008 · 507 citations
Daniele Marin, Rendon C. Nelson, Sebastian T. Schindera et al. · Radiology · 2009 · 490 citations