Journal of Orthopaedic and Sports Physical Therapy · 2015 · 19 citations · 23 references
MedicineOrthopaedic SurgeryRehabilitation MedicineExercise PhysiologyExercise TestingPhysical TherapyExercise TherapyMuscle StrengthMuscle StrengtheningNeuromuscular TrainingStrength TrainingStrengthening ExercisesElectrical Muscle StimulationIsometric Muscle ContractionKnee Extension StrengthMultiple-period Crossover DesignsMuscle Force ProductionMuscle Torque MeasurementStimulation TreatmentsStimulation Waveform Design
STUDY DESIGN: Single-blind, block-randomization crossover design. OBJECTIVE: To compare the knee extensor muscle torque production elicited with 2500-Hz burst-modulated alternating current (BMAC) and with a monophasic pulsed current (MPC) at the maximum tolerated stimulation intensity. BACKGROUND: Neuromuscular electrical stimulation (NMES) is often used for strengthening the quadriceps following knee surgery. Strength gains are dependent on muscle torque production, which is primarily limited by discomfort. Burst-modulated alternating current stimulation is a clinically popular waveform for NMES. Prior research has established that MPC with a relatively long pulse duration is effective for high muscle torque production. METHODS: Participants in this study were 20 adults with no history of knee injury. A crossover design was used to randomize the order in which each participant's dominant or nondominant lower extremity received NMES and the waveform (MPC or BMAC) this limb received. Stimulation intensity was incrementally increased until participants reached their maximum tolerance. The torque produced was converted to a percentage of each participant's maximum volitional isometric contraction of the respective limb. RESULTS: A general linear model for a 2-treatment, 2-period crossover design was utilized to analyze the results. The mean ± SD electrically induced percent maximum volitional isometric contraction at maximal participant tolerance was 49.5% ± 19.6% for MPC and 29.8% ± 12.4% for BMAC. This difference was statistically significant (P = .002) after accounting for treatment order and limb, which had no effect on torque production. CONCLUSION: Neuromuscular stimulation using MPC may be more efficacious than using BMAC to achieve a high torque output in patients with quadriceps weakness.
23
Lynn Snyder‐Mackler, A Delitto, Sandra L. Bailey et al. · Journal of Bone and Joint Surgery · 1995 · 431 citations
Lynn Snyder‐Mackler, Anthony Delitto, Susan W. Stralka et al. · Physical Therapy · 1994 · 268 citations
Jennifer E. Stevens‐Lapsley, Jaclyn E. Balter, Pamela Wolfe et al. · Physical Therapy · 2011 · 265 citations · Full text
Jennifer E. Stevens, Ryan L. Mizner, Lynn Snyder‐Mackler · Journal of Orthopaedic and Sports Physical Therapy · 2004 · 197 citations