IEEE Transactions on Nuclear Science · 1995 · 13 citations · 6 references
EngineeringNuclear EngineeringPhysicsNuclear PhysicsRadiation DosimetryRadiation MeasurementMonte Carlo DosimetryNeutron DetectionNeutron ModerationNeutron TransportEquivalent Dose DeterminationModerator PhysicsNeutron CountingNeutron Detector SystemsNeutron Equivalent DosePolyethyleneThermal Neutron DetectionThermal Neutron Distribution
We have developed a unique neutron counter applicable to measurements of fluence, energy distribution and the dose equivalent of neutrons with very wide energy range, and to estimations of incident direction of neutron beams. This 4/spl pi/ sensitive neutron counter consists of a spherical polyethylene moderator and three charge-division-type position-sensitive proportional counters (PSPCs) inserted into the moderator orthogonally with each other. The three PSPCs give thermal neutron distributions in the spherical moderator that bring us the above information. The characteristics of this neutron counter have been studied with Monte Carlo simulations and with experiments using monoenergetic neutrons.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
6
A new type of neutron spectrometer
R.L. Bramblett, Ronald I. Ewing, T. W. Bonner · Nuclear Instruments and Methods · 1960 · 536 citations
A Neutron Detector Having Uniform Sensitivity from 10 Kev to 3 Mev
A. O. Hanson, J.L. McKibben · Physical Review · 1947 · 354 citations · Full text
Radiation Detection and Measurement
Louis Costrell · Nuclear Science and Engineering · 1980 · 288 citations
Polyethylene moderated 3He neutron detectors
L.V. East, R.B. Walton · Nuclear Instruments and Methods · 1969 · 73 citations