2009 · 15 citations · 15 references
MedicineAnesthesiologySurgeryAnesthesiaCardiothoracic AnesthesiologyPerioperative Outcomes ResearchAnesthetic MonitoringPerioperative MonitoringPostoperative MonitoringPreoperative Anesthesia AssessmentStrokeArterial Oxygen SaturationAssessment Of Oxygen SaturationIntraoperative Cerebral MonitoringOxygen SaturationOxygen Saturation DeficitOxygen Saturation Monitoring
Objective: To determine the usefulness of cerebral oxygen saturation monitoring in a heterogeneous population of patients undergoing on-pump cardiac surgery and the relationship between minimal perioperative cerebral oxygen saturation (rSO2) levels and clinically relevant outcome parameters. Setting: Cardiac anesthesia unit of a University Hospital Design: Retrospective analysis Participants: n=274 patients monitored bi-hemispherically with an INVOS 5100 cerebral oxymeter and n=526 matched patients without cerebral oxygenation monitoring. The decision to monitor a patient was based on individual co-morbidities associated with an increased risk of stroke (cerebral and/or peripheral artery disease, history of stroke) at the discretion of the attending anesthetist. Interventions: None prespecified. Measurements and main results: In a first analysis, all patients that had been monitored by cerebral oximetry in 2006 were determined by analysis of the anesthesia charts and the institutional cardiac surgery database and compared with a control group matched for Euroscore, age, and type of surgery. This analysis revealed that monitored patients had more preoperative risk factors, had a longer duration of surgery, cardiopulmonary bypass and aortic crossclamp, and needed longer high dependency unit care (all p 8. Conclusions: These data suggests that patients with a higher risk profile for cerebral vascular accidents and renal dysfunction undergoing on-pump cardiac surgery may benefit from cerebral oxygenation monitoring and that rSO2 levels < 50% are associated with an unfavourable clinical course. However, the association between low cerebral oxygen saturation and worse outcome seems to be limited to patients with a low to moderate risk profile (Euroscore ≤ 8).
15
Fun-Sun F. Yao, Chia-Chih Tseng, Chee-Yueh A. Ho et al. · Journal of Cardiothoracic and Vascular Anesthesia · 2004 · 355 citations
Medicine, Neuroscience, Surgery +15
Evaluation of a Cerebral Oximeter as a Monitor of Cerebral Ischemia during Carotid Endarterectomy
Satwant K. Samra, Eric A. Dy, Kathy Welch et al. · Anesthesiology · 2000 · 340 citations · Full text
Medicine, Neurosurgery, Surgery +15