IEEJ Transactions on Industry Applications · 2008 · 16 citations · 13 references
Electrical EngineeringEngineeringVienna RectifierEnergy EfficiencyEnergy ConversionPower Electronics ConverterElectric Power ConversionWater-cooled RectifierPower InverterPower ElectronicsCooling SystemRefrigeration
In this paper, a forced air-cooled, 400kHz, 10kW Vienna Rectifier with a power density of 8.5kW/liter is presented. To further improve the power density, the switching frequency is increased to reduce the EMI filter volume. A design for an 18.5kW/liter, 2.5MHz rectifier is proposed. By using today's technology, it is calculated that the maximum power density for a forced air-cooled and water-cooled rectifier is 20.8kW/liter and 24kW/liter respectively. To achieve 30kW/liter, improvements must be made in passive component material properties, reducing semiconductor losses and improving the cooling system.
13
PWM Converter Power Density Barriers
Johann W. Kolar, Uwe Drofenik, J. Biela et al. · 2007 · 376 citations
Electrical Engineering, Engineering, Aerospace Electric Power +15
A Novel PWM Technique in Digital Control
Peng Li, Yong Kang, Xuejun Pei et al. · IEEE Transactions on Industrial Electronics · 2007 · 64 citations