Development of a high-resolution cavity-beam position monitor

Yoichi Inoue, H. Hayano, Y. Honda, Toshikazu Takatomi, T. Tauchi, J. Urakawa, S. Komamiya, Tomoya Nakamura, T. Sanuki, Eun-San Kim,

Physical Review Special Topics - Accelerators and Beams · 2008 · 39 citations · 0 references

DOIFull text

Open access

Concepts

Abstract

We have developed a high-resolution cavity-beam position monitor (BPM) to be used at the focal point of the ATF2, which is a test beam line that is now being built to demonstrate stable orbit control at $\ensuremath{\sim}\mathrm{\text{nanometer}}$ resolution. The design of the cavity structure was optimized for the Accelerator Test Facility (ATF) beam in various ways. For example, the cavity has a rectangular shape in order to isolate two dipole modes in orthogonal directions, and a relatively thin gap that is less sensitive to trajectory inclination. A two stage homodyne mixer with highly sensitive electronics and phase-sensitive detection was also developed. Two BPM blocks, each containing two cavity BPMs, were installed in the existing ATF beam line using a rigid support frame. After testing the basic characteristics, we measured the resolution using three BPMs. The system demonstrated 8.7 nm position resolution over a dynamic range of $5\text{ }\text{ }\ensuremath{\mu}\mathrm{m}$.