Plastic & Reconstructive Surgery · 1996 · 55 citations · 6 references
DentistryMaxillofacial SurgeryDentoalveolar SurgeryMaxillofacial TraumaTraumatic Dental InjuriesInternal FixationMandibular FracturesRoot FracturesTooth FracturesComplications Of Root FracturesFracturesIatrogenic Root DamageMaxillary FracturesRetrospective Case Study
Rigid internal fixation with plates and screws for osteosynthesis of facial fractures and osteotomies in the cranio-maxillofacial skeleton is often undertaken in situations in which the exact position of the underlying tooth roots cannot be determined. Therefore, a screw may be inadvertently placed into a root. There is scant data in the literature addressing the consequences of tooth impingement. This 5-year retrospective study documents the long-term outcome of teeth transfixed by osteosynthesis screws in a series of 387 consecutive facial fractures at a Level I trauma center. The incidence of root impingement per screw was 0.47 percent (13 transfixed teeth per 2340+ screws). Mandibular teeth were more "at risk" than maxillary teeth by a ratio of 10:3. No transfixed teeth became infected or required extraction in this series. In conclusion, inadvertent tooth root impingement by osteosynthesis screws appears to have minimal adverse consequences.
6
The Use of Miniplates in Craniomaxillofacial Surgery
Ian R. Munro · 1987 · 55 citations
Medicine, Orthodontics, Surgery +8