Veterinary Surgery · 2002 · 23 citations · 8 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryBiomechanicsEquine SurgeryOrthopedicsExtremity BiomechanicsFixation BiomechanicsJoint BiomechanicsJoint MechanicsJoint SurgeryArthrodesis BiomechanicsBiomechanical EffectsBiomechanical MechanismsBiomechanical ResponseBiomechanical TestingCompression Plate FixationProximal Interphalangeal Joint Arthrodesis
OBJECTIVE: To compare the biomechanical characteristics and mode of failure of two different dynamic compression plate (DCP) techniques for proximal interphalangeal joint (PIPJ) arthrodesis in horses. STUDY DESIGN: Randomized block-design blocking on horse (1-5), method of fixation (two 7-hole, 3.5-mm broad DCP vs two 5-hole, 4.5-mm narrow DCP), side (left, right), and end (front, hind). Constructs were loaded to failure in 3-point bending in a dorsal-to-palmar (plantar) direction. SAMPLE POPULATION: Ten paired limbs from 5 equine cadavers. METHODS: Two 7-hole, 3.5-mm broad dynamic compression plates (bDCP) were used in 1 limb of a pair, and two 5-hole 4.5-mm narrow dynamic compression plates (nDCP) were used on the contralateral limb. Plates were positioned abaxially across the dorsomedial and dorsolateral aspect of the PIPJ. Arthrodesis constructs were loaded (19 mm/s) in 3-point bending in a dorsal-to-palmar (plantar) direction using a materials-testing machine. Composite stiffness, yield point, and maximal bending moment at failure were obtained from bending moment-angular deformation curves. Data were analyzed using ANOVA, X(2) analysis, and Fisher's exact tests; the power of the test was calculated when differences were not significant. RESULTS: There were no significant differences in composite stiffness (P >.05; power = 0.8 @ delta = 21.9%), yield point (P >.05; power = 0.8 @ delta = 34.4%), or maximal bending moment (P >.05; power = 0.8 @ delta = 17.8%) between the two fixation techniques. For bDCP constructs, 11% (15 of 140) of the 3.5-mm screws were damaged; 7 of the screw heads pulled through plates where the plates bent, 1 screw head broke off, and 7 screws were bent or pulled out of the phalanx. For nDCP constructs, 8% (8 of 100) of the 4.5-mm screws were damaged; 1 screw head pulled through a plate, 1 screw head broke off, and 6 screws were bent or pulled out of the phalanx. CONCLUSIONS: There were no biomechanical or failure differences between bDCP and nDCP fixation of the PIPJ in horses when evaluated in single-cycle 3-point bending to failure. CLINICAL RELEVANCE: There is no biomechanical advantage to the use of two 7-hole, 3.5-mm bDCP in equine proximal interphalangeal arthrodesis compared with two 5-hole, 4.5-mm nDCP. Two 5-hole, 4.5-mm nDCP may be easier to place, whereas two 7-hole, 3.5-mm bDCP may provide more versatility in fracture repair.
8
Force measurements in screw fixation
David M. Nunamaker, S. M. Perren · Journal of Biomechanics · 1976 · 98 citations
Double-plate fixation of comminuted fractures of the second phalanx in horses: 10 cases (1985-1993)
Mark R. Crabill, Jeffrey P. Watkins, Robert K. Schneider et al. · Journal of the American Veterinary Medical Association · 1995 · 32 citations · Full text
Veterinary Medicine, Orthopaedic Surgery, Orthopedic Surgery +10