The Canadian Journal of Chemical Engineering · 2000 · 36 citations · 14 references
EngineeringChemical EngineeringFlow VisualizationProcess DesignTransport PhenomenaFlow MeasurementFluid PropertiesPacked Bed FlowColumn Scale-upDistributor DesignExperimental StudiesFlow DistributionGas FlowLiquid FlowPhysical PropertiesViscosity
Abstract Liquid flow distribution has been a major concern when scaling up random packed columns. This study concerns the measurements of liquid flow distribution in a large scale column packed with 25.4 mm stainless steel Pall rings. The liquid flow distribution was studied with packed bed height from 0.9 to 3.5 m, liquid flow rate from 2.91 to 6.66 kg/m 2 ·s, and gas flow rate from 0 to 3.0 kg/m 2 ·s. In addition, three systems, water/air, aqueous detergent solution/air and Isopar/air, were used to study the effect of liquid physical properties on liquid flow distribution, and two different liquid distributors were employed to test the effect of liquid distributor design. It was found that liquid flow distribution was strongly influenced by liquid distributor design, packed bed height, gas flow rate and liquid viscosity, slightly influenced by liquid flow rate, but not by liquid surface tension.
14
Liquid distribution in a packed column
Kakusaburo Onda, Hiroshi Takeuchi, Yoshiro Maeda et al. · Chemical Engineering Science · 1973 · 57 citations
Liquid distribution in packed columns
E. Dutkai, Eli Ruckenstein · Chemical Engineering Science · 1968 · 53 citations