Medical Physics · 2011 · 50 citations · 21 references
MedicineBiomedical EngineeringComputational EngineeringHeat TransferUltrasonographyUltrasoundMedical Imaging InstrumentationTransducer TechnologyUltrasonicsUltrasound ImagingUltrasound InstrumentationUltrasound PhysicsMedical TransducersPhased Array TransducersPower Deposition ProfilesThermal EffectsTransducer SimulationTransducersUltrasonic TransducersUltrasound Imaging Transducers
PURPOSE: This study presents the results obtained from both simulation and experimental techniques that show the effect of mechanically or electronically steering a phased array transducer on proximal tissue heating. METHODS: The thermal response of a nine-position raster and a 16-mm diameter circle scanning trajectory executed through both electronic and mechanical scanning was evaluated in computer simulations and experimentally in a homogeneous tissue-mimicking phantom. Simulations were performed using power deposition maps obtained from the hybrid angular spectrum (HAS) method and applying a finite-difference approximation of the Pennes' bioheat transfer equation for the experimentally used transducer and also for a fully sampled transducer to demonstrate the effect of acoustic window, ultrasound beam overlap and grating lobe clutter on near-field heating. RESULTS: Both simulation and experimental results show that electronically steering the ultrasound beam for the two trajectories using the 256-element phased array significantly increases the thermal dose deposited in the near-field tissues when compared with the same treatment executed through mechanical steering only. In addition, the individual contributions of both beam overlap and grating lobe clutter to the near-field thermal effects were determined through comparing the simulated ultrasound beam patterns and resulting temperature fields from mechanically and electronically steered trajectories using the 256-randomized element phased array transducer to an electronically steered trajectory using a fully sampled transducer with 40 401 phase-adjusted sample points. CONCLUSIONS: Three distinctly different three distinctly different transducers were simulated to analyze the tradeoffs of selected transducer design parameters on near-field heating. Careful consideration of design tradeoffs and accurate patient treatment planning combined with thorough monitoring of the near-field tissue temperature will help to ensure patient safety during an MRgHIFU treatment.
21
Kullervo Hynynen, Gregory T. Clement, Nathan McDannold et al. · Magnetic Resonance in Medicine · 2004 · 337 citations
Volumetric HIFU ablation under 3D guidance of rapid MRI thermometry
Max O. Köhler, Charles Mougenot, Bruno Quesson et al. · Medical Physics · 2009 · 304 citations