Blood Pressure Monitoring · 2007 · 23 citations · 17 references
EngineeringToxicologyInstrumentationMetrologySensorsCardiovascular MonitoringMedical InstrumentationPressure MeasurementPressure SensorsAutomated Office Blood Pressure MeasurementBlood PressureBlood Pressure MeasurementBlood Pressure MonitoringBlood Pressure MonitorsManometersNoninvasive Blood Pressure MeasurementSystolic Blood Pressure
OBJECTIVE: Alternatives to the traditional, but possibly toxic mercury sphygmomanometer are needed for accurate blood pressure measurements in the medical workplace. We compared the performance of two commercially available potential replacements for the mercury column; an anaeroid manometer (Baum & Co) and an automated oscillometric device (Omron HEM-907), using the mercury sphygmomanometer as a standard, in the same participants. METHODS: Two independent observers performed simultaneous triplicate blood pressure readings for 512 participants. The average difference and standard deviation of the difference comparing the mercury column vs. the anaeroid and automated devices were calculated for each of the three paired systolic and diastolic blood pressure readings. RESULTS: Both devices met the Association for the Advancement of Medical Instrumentation criteria for sphygmomanometers (<5 mmHg average difference, <8 mmHg standard deviation of the difference) for all three readings. Compared with the mercury standard, there were no significant differences (by paired t-test) with the anaeroid device (-0.83/0.73 mmHg, P=0.25/0.09), but the automated device slightly overestimated systolic blood pressure (by 2.12 mmHg, P=0.002) and underestimated diastolic blood pressure (by 2.36 mmHg, P=0.0002). The first reading was significantly higher and had a larger standard deviation than the second or third readings across all manometers. CONCLUSIONS: The automated device performed as well as an anaeroid manometer operated by well trained, experienced observers. The two alternative devices to the mercury sphygmomanometer examined in this study may be potential replacement devices for blood pressure measurement.
17
Recommendations for Blood Pressure Measurement in Humans and Experimental Animals
Thomas G. Pickering, John E. Hall, Lawrence J. Appel et al. · Hypertension · 2004 · 2.1K citations · Full text
Eoin O Brien, J C Petrie, William A. Littler et al. · Journal of Hypertension · 1990 · 769 citations
Engineering, Cardiology, Equipment +16
Eoin OʼBrien, Thomas G. Pickering, Roland Asmar et al. · Blood Pressure Monitoring · 2002 · 744 citations · Full text
ERROR IN BLOOD-PRESSURE MEASUREMENT DUE TO INCORRECT CUFF SIZE IN OBESE PATIENTS
M H Maxwell, P Schroth, A U Waks et al. · The Lancet · 1982 · 308 citations