The practical possibilities of the oscillating vessel method for accurate absolute measurements have been investigated. An improvement in Andrade and Chiong's apparatus was effected by using a capillary tube for the stem of the spherical bulb so that the liquid acted as its own thermometer. Abnormally large logarithmic decrements were found to occur with large amplitudes of rotation, and attention has been given to the best statistical method of calculating the decrement while avoiding this effect. A value of 1.0025 ± 0.0005 CP was obtained for the viscosity of water at 20°C, but an analysis of the sources of error indicates that the accuracy could be increased by further improvements well beyond that of the best capillary tube determination (1.0019 ± 0.0003 CP). These improvements would include the replacement of the spherical bulb by a cylindrical vessel.
6