Publication | Closed Access
Early Complications in Proximal Humerus Fractures (OTA Types 11) Treated With Locked Plates
250
Citations
18
References
2008
Year
The major complication reported in this study was screw penetration, suggesting that exceptional vigilance must be taken in estimating the appropriate number and length of screws used to prevent articular penetration; although the device provides exceptional fixation stability, its indication must be scrutinized for each individual patient, taking the extent of trauma/fracture and age into consideration and carefully weighing it against other forms of treatment.