Optics Letters · 2003 · 135 citations · 11 references
Natural SciencesBioengineeringBiomedical EngineeringBiomedical OpticsBiophotonicsDiagnostic ImagingImagingInterferometryOptical CoherenceOptical Coherence TomographyOptical ImagingOptical TomographyCamerasHeterodyne DetectionHeterodyne InterferometryHeterodyne ReceiversInterferometric MeasurementOptical Coherence Tomography Instrumentation
A two-dimensional heterodyne detection technique based on the frequency-synchronous detection method [Jpn. J. Appl. Phys. 39, 1194 (2000)] is demonstrated for full-field optical coherence tomography. This technique, which employs a pair of CCD cameras to detect the in-phase and quadrature components of the heterodyne signal simultaneously, offers the advantage of phase-drift suppression in interferometric measurement. Horizontal cross-sectional images are acquired at the rate of 100 frames/s in a single longitudinal scan, with a depth interval of 6 microm, making the rapid reconstruction of three-dimensional images possible.
11
David Huang, Eric A. Swanson, Charles P. Lin et al. · Science · 1991 · 13.7K citations
In Vivo Endoscopic Optical Biopsy with Optical Coherence Tomography
Guillermo J. Tearney, Mark E. Brezinski, Brett E. Bouma et al. · Science · 1997 · 1.4K citations