Hippuran transit times in the kidney: a new approach

L.H.M. van Stekelenburg

Physics in Medicine and Biology · 1978 · 14 citations · 2 references

Concepts

Abstract

Deconvolution of a renogram curve with the Hippuran concentration of the plasma is a procedure for finding the impulse response function H(t), which represents the probability that a Hippuran molecule, entering the kidney at zero time, is still present in the organ at a time t. The initial value of this function is one by definition. It may remain constant for a while but it should never increase and ultimately it should approach zero. Fleming and Goddard (1973) introduced a deconvolution technique for the renogram in which the Laplace transformation of the function I(t), the Hippuran concentration in the plasma, plays a role. This means that a mathematical expression must be found which is not too complicated for the required operations and is nevertheless a sufficiently close approximation of I(t). A three-exponential function I(t) is proposed. Much effort is saved by first computing the integral G(t) of the impulse response function. It is easily differentiated graphically and moreover it provides a simple means for finding the average transit time.

References

2