British Journal of Clinical Pharmacology · 2006 · 26 citations · 7 references
PharmacyPharmacokineticsPharmacologyDrug DeliveryPain ManagementTransdermal Drug DeliveryAnalgesiaAnalgesic PharmacologyOpioid AnalgesicsPharmacologic Pain TherapyTransdermal Dosage FormsTransdermal FormulationsComparative Analgesic EfficacyComparative Bioequivalence Study DesignMatrix FormulationPharmacokinetic ParametersReplicate Crossover Study DesignTest-to-reference Ratio AnalysisTransdermal Delivery SystemsTransdermal Drug Delivery Systems
AIM: To determine the pharmacokinetics, safety and performance of a novel matrix formulation of fentanyl. METHODS: Transdermal fentanyl was administered as the novel matrix and the Durogesic reservoir formulations (24 subjects, 100 microg h(-1)) in a randomized, fully replicate, four-way crossover study. Serum concentrations of fentanyl were assayed by LC/MS/MS. Pharmacokinetic parameters of fentanyl and performance (adherence and skin irritability) were evaluated. RESULTS: Test/reference ratio (90% confidence intervals) for AUC(0-t), AUC(inf) and C(max) were 105.5% (99.4, 112.0), 105.3% (99.3, 111.6) and 111.4% (100.4, 123.6), respectively. Adherence and skin irritability results of the two formulations were similar. CONCLUSION: The two formulations are expected to result in similar efficacy for the management of severe pain.
7
Jean‐Francois Marier, Mary Lor, Diane Potvin et al. · The Journal of Clinical Pharmacology · 2006 · 52 citations
Rainer Freynhagen, Hans Jürgen von Giesen, P. Busche et al. · Journal of Pain and Symptom Management · 2005 · 45 citations · Full text
John Lambropoulos, Nick V. Lazaridis, Thomas S. Ingallinera et al. · Journal of Pharmaceutical and Biomedical Analysis · 1999 · 43 citations