Veterinary MedicineVeterinary Clinical SciencesVeterinary Critical CareEquine Internal MedicineEquine MedicineEquine ScienceBlood Glucose MonitoringContinuous Glucose MonitoringGlycemic MonitoringMetabolic MonitoringBlood Glucose Meter AccuracyBlood Sampling From Venous LinesConfoundingGlucose Analysis In Body FluidsLaboratory Plasma Glucose TestingPoint-of-care Glucose MeasurementStandard Method Of MeasurementWhole Blood Collection
BACKGROUND: More information is needed regarding accuracy of commonly used methods of glucose measurement in the critically ill horse. HYPOTHESIS: Glucometry will have good agreement with a laboratory standard. Glucometry with plasma will have better agreement than when performed with whole blood. ANIMALS: Fifty sequentially admitted equine emergency patients, aged >1year. METHODS: Venous blood was collected at admission and immediately analyzed by point-of-care glucometry on both whole blood (POC/WB) and plasma (POC/PL), a multielectrode blood gas analyzer with whole blood (BLG), and a standard laboratory method with plasma (CHEM). Paired data were compared using Lin's concordance correlation, Pearson's correlation, and robust regression. Bias and limits of agreement were tested by the Bland-Altman technique. Bivariate regression analysis was used to explore confounding factors. RESULTS: Concordance was significant for all comparisons, and was strongest for CHEM-POC/PL (0.977) and weakest for POC/WB-POC/PL (0.668). Pearson's correlation was excellent for all comparisons except those with POC/WB. All comparisons had excellent robust regression coefficients except those with POC/WB. CONCLUSIONS AND CLINICAL IMPORTANCE: POC glucometry with plasma had excellent agreement with a laboratory standard, as did blood gas analysis. POC glucometry with whole blood correlated poorly with a laboratory standard. These differences may be clinically important, and could affect decisions based on glucose concentrations.
29
Intensive Insulin Therapy in Critically Ill Patients
Greet Van den Berghe, Pieter Wouters, Frank Weekers et al. · New England Journal of Medicine · 2001 · 10K citations · Full text
A Concordance Correlation Coefficient to Evaluate Reproducibility
Biometrics · 1989 · 8.7K citations
Intensive Insulin Therapy in the Medical ICU
Greet Van den Berghe, Alexander Wilmer, Greet Hermans et al. · New England Journal of Medicine · 2006 · 3.7K citations · Full text