Concepedia

Publication | Open Access

Removal of Immunoglobulins by a Protein A Versus an Antihuman Immunoglobulin G‐Based System: Evaluation of 602 Sessions of Extracorporeal Immunoadsorption

38

Citations

14

References

2000

Year

Abstract

Elimination of IgG can be achieved by extracorporeal immunoadsorption (IA) based on specific binding to either staphylococcal protein A (Excorim) or sheep polyclonal antibodies directed against human IgG (Therasorb). In 602 analyzed sessions of IA, elimination of IgG was 60% through 80% depending on the treated plasma volume, with no significant difference between the mentioned systems. However, the decrease of IgM and IgA was approximately 50% in the anti-IgG compared to 20-40% in the protein A system. Plasma albumin concentration decreased by 20% in the anti-IgG system compared to 15% in the protein A system, and hemoglobin values increased by 2% in the anti-IgG system and decreased by 6% in the protein A system. In conclusion, a clinical relevance for these findings cannot be ruled out, and the individual choice might depend on the clinical situation and laboratory findings.