Publication | Open Access
Note: An improved driver section for a diaphragmless shock tube
22
Citations
6
References
2015
Year
Shock Wave GenerationEngineeringAerospace EngineeringPhysiologyMechanical EngineeringMechanical SystemsMeasurement ReproducibilityPneumaticsDiaphragmless Shock TubeChemical KineticsShock Compression
Improvements to equipment lifetime and measurement reproducibility have been made by modifying the actuating mechanism of a diaphragmless shock tube that is used for high temperature gas kinetic studies. The modifications have two major benefits while retaining the simplicity of the original apparatus. First, the reproducibility of shock wave generation has been greatly improved and is demonstrated with 50 nearly identical experiments on the dissociation of cyclohexene at T2 = 1765 ± 13 K and P2 = 120 ± 1 Torr, demonstrating the capability for signal averaging over many experiments. Second, the lifetime of the bellows which forms the heart of the actuator is considerably improved, significantly increasing the time between replacements.