Natural SciencesChemical EngineeringMaterials ScienceElectrochemical EngineeringElectrochemistrySurface ScienceCorrosion EngineeringCorrosion KineticsElectrochemical CorrosionElectrode KineticsSurface RoughnessSurface Roughness EffectsMass Transfer MechanismsMass Transport AnalysisMass Transport In Electrochemical SystemsMass Transport PhenomenaOxygen Mass TransferPipe RoughnessRoughnessVertical Pipe Flow
Abstract Rates of pipewall oxygen mass transfer in a 39 mm ID vertical pipe carrying an aqueous slurry containing 20 vol% 30‐50 mesh sand have been determined electrochemically with twin in‐line flow cells, one containing a mild steel specimen previously roughened by erosion‐corrosion and the other a smooth specimen. Measurements were also made without the solids present. The three‐dimensional rough surface, with roughness height approximately 0.2 mm, and pitch/height in the range 5 to 10, resulted in mass transfer enhancement up to 100%, in both the slurry and the solution, with the maximum effect occurring at the dimensionless roughness height e + ≈︁ 30.