Scanning Kelvin Probe Measurements of the Stability of Adhesive/Metal Interfaces in Corrosive Environments

K. Wapner, G. Grundmeier

Advanced Engineering Materials · 2004 · 35 citations · 14 references

Concepts

Abstract

The strength of structural adhesive joints for the bonding of metals such as steel or aluminium is mainly reduced by the degradation of the polymer/metal interface due to the ingression of water and subsequent electrochemical reactions. In this work, adhesive/metal interfaces were modified with ultra‐thin adhesion promoting and corrosion resistant bilayer films. A Scanning Kelvin Probe was used for the in‐situ measurement of the interfacial ingression of water and ions as well as for the characterisation of electron transfer processes that lead to a corrosive de‐adhesion.

References

14