Journal of Power and Energy Systems · 2012 · 44 citations · 8 references
EngineeringCivil EngineeringComputational Fluid DynamicsFluid DynamicsSubsurface Fluid FlowCorrosion EvaluationFlow BehaviorFlow MeasurementPipe FlowAccelerated Corrosion TestingFlow Velocity DistributionFlow Velocity MeasurementsFlow-accelerated CorrosionLaser Doppler VelocimetryShear StressWall Shear StressWall Shear Stress Estimation
Flow accelerated corrosion (FAC) rate downstream from an orifice was measured in a high-temperature water test loop to evaluate the effects of flow field on FAC. Orifice flow was also measured using laser Doppler velocimetry (LDV) and simulated by steady RANS simulation and large eddy simulation (LES). The LDV measurements indicated the flow structure did not depend on the flow velocity in the range of Re = 2.3×104 to 1.2×105. Flow fields predicted by RANS and LES agreed well with LDV data. Measured FAC rate was higher downstream than upstream from the orifice and the maximum appeared at 2D (D: pipe diameter) downstream. The shape of the profile of the root mean square (RMS) wall shear stress predicted by LES had relatively good agreement with the shape of the profile of FAC rate. This result indicates that the effects of flow field on FAC can be evaluated using the calculated wall shear stress.
8
Shunsuke Uchida, Masanori Naitoh, Yasushi Uehara et al. · Journal of Nuclear Science and Technology · 2009 · 25 citations · Full text