Clinical Orthopaedics and Related Research · 1978 · 11 citations · 0 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryBone GraftingOrthopedic BiomechanicsOrthopedicsBone CementsBone MechanicsFixation BiomechanicsFracture FixationInternal FixationBone Cement FixationBone Plate FixationCemented Femoral FixationCemented FixationCortical Bone DefectsCortical Bone DestructionFemoral Pathologic FracturesPathologic Fracture Management
To determine the most stable mode of internal fixation for the pathologic femoral shaft fracture with extensive cortical destruction, 2 fixation techniques incorporating methylmethacrylate were compared. Osteotomies through standardized cortical defects were created in intact embalmed femora to simulate a standard pathologic fracture. Fixation obtained with either intramedullary Schneider rods or 28-hold ASIF plates, both using bone cement, was compared in torsion and bending. In torsion, plate-fixed femora failed at a mean load of 71.2 newton-meters compared to 26.8 newton-meters for the Schneider rod counterparts. In bending, plate-fixed bones at a mean load of 8133.9 newtons compared to 1921.4 newtons for rod-fixed femora. Fixation with double plates and methylmethacrylate was clearly more stable and allowed for immediate pain-free ambulation.