Abstract

Results are presented from experimental studies of ac corona discharges between a point electrode and a dielectric-coated plate in nitrogen, argon, helium, and air in the voltage frequency range f=50 Hz–50 kHz. The characteristic features of this type of discharge are compared with the well-known features of dc positive and negative coronas and a barrier discharge between plane electrodes. It is shown that the presence of a dielectric barrier on the plane electrode significantly changes the electric characteristics and spatial structure of the corona, whereas the main phases of the discharge evolution remain unchanged as the voltage increases. With a point electrode, the breakdown voltage of the barrier corona decreases substantially as compared to the breakdown voltage of a barrier discharge with plane electrodes. This leads to softer conditions for the streamer formation in a barrier corona, which becomes more stable against spark generation.