Journal of Applied Mechanics · 1974 · 103 citations · 0 references
EngineeringBiomedical EngineeringPhysicsFluid DynamicsMedical PhysicsBiofluid MechanicsCirculatory PhysiologyHemodynamicsMicrocirculatory PhysiologyMicrocirculatory TransportBlood FlowBlood Flow DynamicsMicrocirculationMicrocirculatory FlowMicrocirculatory HemodynamicsMicrocontinuum MechanicsPulsatile FlowVelocity Profiles
The steady and pulsatile flow of blood through small rigid, circular tubes has been analysed by a microcontinuum approach. The exact solutions for velocity and cell rotational velocity are obtained. A comparison of the theoretical velocity profiles with the experimentally determined profiles for both steady and pulsatile blood flow is quite encouraging.