EngineeringMaterials SciencePhysicsNuclear PhysicsRadiation DetectionRadiation PhysicsAlpha Particle DetectionCharged Particle DetectionParticle DetectorsRadiation Damage In MaterialsRadiation DetectorsSemiconductor DetectorsDetectorsHeavy Ion RadiationLithium-drifted DetectorsRadiation DamageRadiation Damage EffectsRadiation Damage Effects On DetectorsRadiation Damage In DetectorsSilicon Detectors
Deterioration of charged-particle resolution-width, for p-i-n detectors prepared by lithiumion-drift techniques, was observed during bombardment with protons, and alpha particles. During exposure the resolution-width increased without loss of rectification when damage was confined to the intrinsic region. Significant deterioration in response was observed for 108 particles/cm2. Rapid loss of rectification was observed during exposure to neutrons at energies mostly in the range of from 1 to 10 MeV and for a flux of 109 neutrons/cm2/sec. The damage effects were studied with several detectors having an electron resolution-width of 15 to 20 keV at room temperature, and a window thickness of approximately 1 mg/cm2. Limitations on recovery, by further drift treatment, were observed for an integrated charged-particle flux in excess of 1012 particles/cm2. The response of these detectors to electrons before and after damage, and to heavy charged particles during production of damage and after recovery, is described.
3
Lithium-Drifted p-i-n Junction Detectors
H. M. Mann, J.W. Haslett, F. J. Janarek · IRE Transactions on Nuclear Science · 1962 · 15 citations