Concepedia

Publication | Closed Access

Zirconia‐implant‐supported all‐ceramic crowns withstand long‐term load: a pilot investigation

121

Citations

41

References

2006

Year

Abstract

Within the limits of this pilot investigation, it seems that zirconia implants restored with the Procera crowns possibly fulfill the biomechanical requirements for anterior teeth. However, further investigations with larger sample sizes have to confirm these preliminary results. As three Empress-1 crowns showed crack development in the loading area of the steatite balls in the artificial mouth, their clinical use on zirconia implants has to be questioned.

References

YearCitations