Applied Optics · 1997 · 27 citations · 12 references
EngineeringElectrical EngineeringEquipmentGeodesyInstrumentationAngle MeasurementAngular MeasurementInterferometryAccuracyAngle Measurement InstrumentsAngular Measurement SystemsInterferenceInterference Patterns
Based on the idea of measuring small rotation angles with a parallel interference pattern (PIP), a method is developed to measure large rotation angles accurately. Two parallel PIP's that have different periods are used to measure a rotation angle of an object. The measurement made with a small-period PIP provides a high accuracy, and the measurement made with a large-period PIP provides a wide range. An accurate measurement for wide-range angles is made by combining the two measured values. The accuracy of the phase detection is determined by the periods of two PIP's. Rotation angles from approximately -30 to 30 arc min can be measured with an accuracy of 0.2 arc sec. Analytical results are supported by experimental results.
12
Two-wavelength phase shifting interferometry
Yeou-Yen Cheng, James C. Wyant · Applied Optics · 1984 · 432 citations
Engineering, Physics, Metrology +16
New optical method for measuring small-angle rotations
Shi Pan, Erik Stijns · Applied Optics · 1988 · 77 citations
Interferometric Angular Measurement
G. D. Chapman · Applied Optics · 1974 · 59 citations