Experimental study of differences in DNB heat flux between upflow and downflow in vertical rectangular channel.

Yukio SUDO, Keiichi Miyata, Hiromasa Ikawa, Masanori Kaminaga, Masami OHKAWARA

Journal of Nuclear Science and Technology · 1985 · 55 citations · 13 references

DOIFull text

Open access

Concepts

TL;DR

Experiments investigated DNB heat flux in upflow and downflow within a rectangular vertical channel representing a JRR‑3 fuel subchannel, as part of the reactor’s planned 20 MWt upgrade with 20 % LEU fuel. The study aimed to evaluate DNB heat flux under pressure and velocity conditions critical to JRR‑3 safety design. The authors developed a DNB heat flux correlation scheme for upflow and downflow by integrating experimental data with existing literature, evaluated correlation errors, introduced a new upflow correlation, and identified a high‑flow‑rate region where upflow and downflow fluxes converge. The resulting correlation scheme is applicable to JRR‑3 rectangular channels and to other channel geometries. Keywords include research reactors, DNB heat flux, upflow, downflow, rectangular channel, flooding, vertical channel, circular tube, safety design, safety analysis, and flow rates.

Abstract

Abstract Experiments were carried out on DNB (Departure from Nucleate Boiling) heat flux for both upflow and downflow in a rectangular vertical channel simulating a subchannel in the fuel element of the research reactor JRR-3, which is scheduled to be upgraded at 20MWt with 20% low enriched uranium (LEU) fuel. The experiments were carried out for the conditions of pressure and velocity which are important for the safety design of the JRR-3. With the investigation of the data of the present experiment along with already existing data for both rectangular channels and other channels, a scheme of DNB heat flux correlations was obtained for upflow and downflow. With the all available data, the errors of the correlations adopted in this scheme were so evaluated as to utilize these results in the safety analysis of the JRR-3. This scheme includes a new correlation of DNB heat flux for upflow and the identification of a region of high coolant flow rate where no remarkable differences in the DNB heat flux are observed between upflow and downflow. This scheme is considered to be applicable not only to the rectangular channels of the JRR-3 but also to other channels. KEYWORDS: research reactorsDNB heat fluxupflowdownflowrectangular channelfloodingvertical channelcircular tubesafety designsafety analysisflow rates

References

13