Respiration · 2007 · 21 citations · 12 references
MedicineClinical SciencesSurgeryCardiothoracic SurgeryPulmonologyVascular SurgeryAirway DiseasesAirway ObstructionMechanical VentilationRespiratory DiseaseStent PlacementThoracic SurgeryAirway Compression ManagementAirway Stent PlacementMetallic Stent DesignStent SizingTracheal CompressionTracheal StentingTracheobronchial Stenting
A 43-year-old man was referred to our institution with severe extrinsic compression of the trachea at the level of the main carina secondary to an aortic aneurysm, causing respiratory distress and requiring mechanical ventilation. The patient had a past history of Marfan's syndrome and tracheomegaly (the estimated tracheal diameter bronchoscopically was 28 mm). Palliation of the compression was successfully achieved by a custom-made, self-expandable, fully covered metallic stent with a diameter of 28 mm and a length of 60 mm. The patient was weaned off ventilation. The stent stayed in place for 2 years without major complications. This case represents the first stent ever inserted in a very rare condition combining tracheomegaly and extrinsic compression in Marfan's syndrome. It is also the first report of successful placement of the largest tracheal stent which was manufactured exclusively for the airway.
12
Endoscopic Treatment of Malignant Airway Obstructions in 2,008 Patients
Sergio Cavaliere, Federico Venuta, Pierfranco Foccoli et al. · CHEST Journal · 1996 · 399 citations
Pulmonary disease in patients with Marfan syndrome.
Jeremy Wood, D. Bellamy, Anne H. Child et al. · Thorax · 1984 · 180 citations · Full text