Applied Optics · 1986 · 68 citations · 10 references
Natural SciencesEarth SciencesAtmospheric ScienceEnvironmental MonitoringRemote SensingCalibrationInfrared Remote SensingRadiometric CalibrationSatellite Data CalibrationSatellite InstrumentationSatellite SensorsAerosol Optical PropertiesAerosol Optical ThicknessCalibration Coefficient EstimationCalibration CoefficientsCalibration Method ValidationGeostationary Satellite CalibrationOptical Thickness MeasurementSatellite Radiance Calibration
Satellite radiometer calibrations are performed after launch. The study presents a method to calibrate satellite radiometers measuring sunlight scattered radiance. The method uses sunlight scattered by atmospheric gas above oceans as a calibration source and validates coefficients by comparing aerosol optical thickness from VISSR with ground measurements. Calibration coefficients for two VISSR instruments (1980–1983) show significant gain variation for the first instrument (±12%) and stable gain for the second (±2%), with good agreement between VISSR and ground aerosol optical thickness confirming method accuracy.
A method is presented for calibrating satellite radiometers that measure radiance of sunlight scattered from the earth-atmosphere system. The calibrations are made after satellite launch. The calibration source is the radiance of sunlight scattered by the atmospheric gas above oceans inasmuch as aerosols and the surface scatter much less light than the gas under restricted conditions. Calibration coefficients are given for two Visible Infrared Spin-Scan Radiometers (VISSR) carried by Geostationary Operational Environmental Satellites during the years 1980–1983. The gain of the first VISSR during 1980 and part of 1981 varied significantly by ±12%. The second VISSR started observations after 5 Aug. 1981. Its daily values of gain ranged by only ±2% from its mean value during a period of three summers, which shows the stability of the calibration method as well as that of the satellite sensor. The accuracy of the calibration coefficients was estimated by comparing values of aerosol optical thickness measured by VISSR with those measured from the ground. The good agreement between the two sets of data demonstrated the accuracy of the calibration method.
10
Computer-Intensive Methods in Statistics
Persi Diaconis, Bradley Efron · Scientific American · 1983 · 1.2K citations
Effective reflectance of oceanic whitecaps
Peter Koepke · Applied Optics · 1984 · 376 citations