Pacing and Clinical Electrophysiology · 1988 · 16 citations · 4 references
MedicineCardiologySurgeryCardiac TransplantationElectrophysiologyTransplant SurgeryAtrial ElectrophysiologyAtrial FibrillationCardiac ArrhythmiasElectrocardiographyHeart TransplantationTransplant RejectionElectrical StimulationHeart Transplant RejectionIntracardiac ElectrogramsIntracardiac PacingPacingProgrammed Electrical StimulationSinus Node Function TestingTransplantation
When donor hearts are studied systematically after transplantation, by programmed electrical stimulation, sinus node dysfunction has been found to be common though data regarding symptoms related to this phenomenon are not available. In this case report we describe a heart transplant recipient who experienced serious symptomatic sinus node dysfunction associated with transient atrial fibrillation 17 days after cardiac transplantation; there was no evidence of donor heart rejection. Intracardiac electrophysiology testing confirmed sinus node dysfunction of the donor heart, but only with relatively rapid atrial pacing rates.
4
Sinus node function in first three weeks after cardiac transplantation.
Alan Mackintosh, David Carmichael, R Cory-Pearce et al. · Heart · 1982 · 77 citations · Full text
Medicine, Cardiology, Surgery +15
Sinoatrial function after cardiac transplantation
R. S. Bexton, Anthony W. Nathan, Kevin J. Hellestrand et al. · Journal of the American College of Cardiology · 1984 · 59 citations
Medicine, Cardiology, Surgery +13
The electrophysiologic characteristics of the transplanted human heart
R. S. Bexton, Anthony W. Nathan, Kevin J. Hellestrand et al. · American Heart Journal · 1984 · 30 citations
Medicine, Cardiology, Physiology +14