Review of Scientific Instruments · 2009 · 10 citations · 7 references
Natural SciencesElectrical EngineeringPhysicsInstrumentationMicrowave EngineeringPlasma PhysicsInterferometryMicrowave MeasurementsPlasma DiagnosticsPlasma WavesHeterodyne DetectionHeterodyne InterferometryHeterodyne ReceiversInterferometer DesignInterferometric CalibrationInterferometric InstrumentationInterferometric MeasurementPhase Shifts
A four-channel microwave interferometer (center frequency: 60 GHz) has been constructed to measure plasma density profiles in the levitated dipole experiment (LDX). The LDX interferometer has a unique design owing to the unique geometry of LDX. The main design features of the interferometer are: (1) the transmitted beam traverses the plasma entirely in O-mode; (2) the interferometer is a heterodyne system employing two free-running oscillators; (3) four signals of data are received from just on transmitted beam; (4) phase shifts are detected in quadrature. Calibration tests demonstrate that the interferometer measures phase shifts with an uncertainty of approximately 5 degrees . Plasma densities in LDX corresponding to phase shifts of up to 5pi are routinely and successfully measured.
7
Production and study of high-beta plasma confined by a superconducting dipole magnet
D. Garnier, A. K. Hansen, M. E. Mauel et al. · Physics of Plasmas · 2006 · 66 citations
Design and initial operation of the LDX facility
D. Garnier, A. K. Hansen, J. Kesner et al. · Fusion Engineering and Design · 2006 · 40 citations