Gut · 1989 · 105 citations · 15 references
MedicineAnatomyUltrasonographyUltrasoundVascular SurgeryDoppler UltrasonographyDoppler UltrasoundFlow MeasurementHemodynamicsVascular UltrasonographyVascular UltrasoundBlood FlowBlood Flow Doppler AssessmentDoppler Blood Flow AssessmentPortal HemodynamicsPortal Vein HemodynamicsPortal Venous DopplerPortal Venous Flow DynamicsVenous Duplex Ultrasound
The volume flow rate of blood in the portal vein was measured using a duplex ultrasound system. The many errors inherent in the duplex method were assessed with particular reference to the portal vein and appropriate correction factors were obtained by in vitro calibration. The effect of posture on flow was investigated by examining 45 healthy volunteers in three different positions; standing, supine and tilted head down at 20 degrees from the horizontal. The mean volume blood flow in the supine position was 864 (188)ml/min (mean 1SD). When standing, the mean volume blood flow was significantly reduced by 26% to 662 (169)ml/min. There was, however, no significant difference between flow when supine and when tilted head down at 20 degrees from the horizontal.
15
Portal venous hemodynamics in chronic liver disease: effects of posture change and exercise.
K Ohnishi, M Saito, T Nakayama et al. · Radiology · 1985 · 153 citations
Transcutaneous Doppler ultrasound measurement of superior mesenteric artery blood flow in man.
Mehwish Qamar, A. E. Read, R. Skidmore et al. · Gut · 1986 · 143 citations · Full text