The Astronomical Journal · 1964 · 10 citations · 0 references
Natural SciencesAstronomyInstrumentationRadiation MeasurementRadio AstronomyInterferometryObservatory InstrumentationInterferometric InstrumentationRadio InterferometryRight AscensionStandard Errors Of Measurement
The two 90-f t steerable paraboloids of the Owens Valley Radio Observatory were used as an east-west interferometer to measure the right ascension of 226 radio sources. The observations were made between January 1960 and July 1961 at spacings of 195X (958 Mc,'sec) and 283X (1390 Mc/sec). Corrections for reso- lution and known confusing sources have been evaluated. The standard errors for a source position range be- tween 3 sec of arc and 20 sec of arc, with an average value of 9 sec of arc.