Journal of Liquid Chromatography & Related Technologies · 1996 · 30 citations · 3 references
PharmacyPharmaceutical AnalysisPharmaceuticsChromatographic AnalysisClinical PharmacologyMass Spectrometric AnalysisAnalytical ChromatographyBioanalytical Method ValidationChromatographic Analysis Of PharmaceuticalsChromatographyLiquid ChromatographyDynamic RangeExtractHigh-performance Liquid ChromatographyHigh-performance Liquid Chromatography Method DevelopmentLinear Dynamic RangeLinear RangeLiquid Chromatography-mass Spectrometry AnalysisPlasma Sampling
Abstract A high performance liquid chromatographic (HPLC) method was developed and validated for the analysis of duloxetine and desmethyl duloxetine in human plasma. Plasma was adjusted to pH 10 with 1.0 M sodium carbonate and extracted with hexane which contained 2% isopropyl alcohol. The concentrated extract was derivatized with dansyl chloride (500 μg/mL). A Phenomenex Primesphere 5 C18 HC column provided chromatographic separation of the analytes followed by fluorescence detection with excitation and emission wavelengths at 285 nm and 525 nm respectively. The linear dynamic range for both analytes was 2 ng/mL to 64 ng/mL with precision and accuracy of <10%.
3
LY248686, A New Inhibitor of Serotonin and Norepinephrine Uptake
David T. Wong, Frank P. Bymaster, Douglas A. Mayle et al. · Neuropsychopharmacology · 1993 · 221 citations · Full text
Medicine, Neuroscience, Pharmacology +11
Ray W. Fuller, Susan K. Hemrick-Luecke, Harold D. Snoddy · Journal of Pharmacology and Experimental Therapeutics · 1994 · 69 citations
Medicine, Neuroscience, Pharmacology +17