Vox Sanguinis · 2000 · 18 citations · 8 references
MedicineHematologyImmunologyClinical ImmunologyPatient SafetyTransfusion MedicineAntibody ScreeningBlood Transfusion SafetyDiagnostic Error DetectionDiagnostic Error PreventionPretransfusion TestingTransfusion ReactionsAntibody CrossmatchingCrossmatch AssaysLabelsPatient Safety IncidentsRed Blood Cell Transfusion SafetySerologic CrossmatchTransfusion Error PreventionTransfusion Reaction Prevention
BACKGROUND AND OBJECTIVES: A crossmatch is usual in pretransfusion testing, but we eliminated it at our tertiary care university hospital. In place of the crossmatch, we have introduced a system where, if an antibody screen is negative, two technologists confirm the ABO of the same patient sample, and we release blood of the patient's type without a serologic or electronic crossmatch. MATERIALS AND METHODS: In 65,628 samples received for pretransfusion testing, we studied the effect of common errors that occur from the time of receipt of a sample until release of the blood unit, in order to decide if elimination of the serologic crossmatch would affect patient safety. All sample labels were inspected for acceptability. RESULTS: A total of 1,082 (1.64%) samples were rejected for mislabeling. Discordance in patient ABO typing results between two technologists was 0.43%. Such discrepancies were resolved before the release of blood units. No donor unit mislabeling or unit release errors were detected. CONCLUSION: Elimination of the crossmatch for red cell antibody-negative patients is safe provided a system of error detection is used. This enhances patient care through the quicker release of blood, increased laboratory efficiency and decreased costs.
8
Reports of 355 transfusion‐associated deaths: 1976 through 1985
Kathleen Sazama · Transfusion · 1990 · 736 citations
Electronic verification of donor‐recipient compatibility: the computer crossmatch
Suzanne H. Butch, W. J. Judd, Elizabeth Steiner et al. · Transfusion · 1994 · 69 citations