Construction and Operation of a Submerged Aerated Filter Sewage‐Treatment Works

A. B. ROBINSON, W. J. BRIGNAL, Alan Jay Smith

Water and Environment Journal · 1994 · 12 citations · 0 references

Concepts

Abstract

ABSTRACT The capacity of the sewage‐treatment works at Silchester in Hampshire has been enhanced and the effluent quality improved to a high standard by the installation of a new submerged biological aerated filter plant. Ten prefabricated steel submerged aerated filters reduce BOD and fully nitrify settled domestic sewage from a population equivalent of 20 000. Comprehensive operating data are presented to demonstrate the ability of single‐stage submerged downflow aerated biological filters to produce a nitrified effluent. The final effluent quality remains consistently within consent limits at 4.8 mg/l BOD, 7.0 mg/l SS and 0.5 mg/l NH 3 ‐N, all 95 percentiles. (Consent 7 mg/l BOD, 25 mg/l SS, and 5 mg/l NH 3 ‐N, 95 percentiles.) Data are presented on total coliform and E. Coli concentrations through the filter plant, showing better than 3 log reductions in the effluent.