Review of Scientific Instruments · 1969 · 58 citations · 5 references
Natural SciencesMaterials SciencePhysicsElectromagnetismMagnetic MaterialsSensorsMagnetic CharacterizationMagnetic SensorsTemperature MeasurementTemperature SensorsEmpirical Prediction EquationsMagnetic Materials CharacterizationMagnetic Property CharacterizationMagnetoresistanceMagnetoresistive SensorsResistance ThermometrySensitivityThermomagnetic Properties
Measurements of the transverse (sample current I normal to magnetic field H) and longitudinal (I∥H) magnetoresistance of 110, ⅛, and ¼ W Allen-Bradley carbon resistors were performed at various temperatures between 1.8 and 18 K in static magnetic fields up to 150 kG. Eleven different resistors having nominal values at room temperature of 47, 100, and 220 Ω were investigated. A description is given of a new technique which was devised to perform these measurements. The magnetoresistance of Allen-Bradley resistors is small, reproducible, and can be estimated from measurements on other resistors of the same nominal value. These resistors are useful, therefore, as thermometers in intense magnetic fields at low temperatures. A comparison is made between different empirical equations which have been used in attempts to fit the data. In addition, different methods are described for determining the temperature T and sensitivity R−1(∂R/∂T)H from the magnetoresistance data.
5