Pediatric Pulmonology · 2003 · 30 citations · 24 references
PharmacyPediatricsPharmacologyPediatric Clinical PharmacologyPediatric PulmonologyPulmonary Function TestingAsthma ManagementDry Powder InhalersMetered-dose InhalersPeak Expiratory FlowRespiratory MonitoringRespiratory Monitoring InstrumentsInhalation Flow DependenceInhaler ResistanceInspiratory Flow LimitationInspiratory Flow ResistanceInspiratory Resistance Testing
Drug release from dry powder inhalers depends for a large part on a sufficiently high peak inspiratory flow (PIF). We determined the variation of PIF through two commonly prescribed dry powder inhalers in children with asthma. We analyzed the effect of inhaler device, age, and severity of asthma symptoms on variation of PIF. Fifty-eight children with asthma (4-15 years old) recorded PIF values together with asthma symptoms in a diary twice daily for 4 weeks. PIF was measured with a portable PIF-meter (In-Check) equipped with adapters to simulate flow resistance through the Accuhaler and Turbohaler inhalers. Children generated higher PIF values through an Accuhaler adapter than through a Turbohaler adapter (95% CI for difference, 25.7-31.7). Mean PIF values increased with age, independent of type of inhaler. The mean (SD) variation of PIF (low%high) was 72.3 (8.1)% for patients using the Accuhaler adapter, and 67.0 (14.5)% for patients using the Turbohaler adapter (mean difference, 5.2%; 95% CI, -0.9 to 11.4). Children < or =7 years of age had a significantly greater variation of PIF in addition to a lower mean PIF (P = 0.0003). PIF decreased significantly when symptoms of asthma increased (mean maximal decrease 11 l/min; P < 0.01), but the correlation between PIF and morning and evening symptoms was weak (r = -0.18 and r = -0.16, respectively). Patients who reported moderate or severe symptoms during the study period had a significantly greater variation of PIF compared to patients who remained free of symptoms or reported mild symptoms. The majority of patients generated PIF >30 l/min during the study, even when they experienced symptoms of asthma. The variation of PIF through the Accuhaler and Turbohaler adapter was significantly greater for children < or =7 years of age and for patients experiencing moderate or severe symptoms of asthma.
24
Predicted normal values for maximal respiratory pressures in caucasian adults and children.
S H Wilson, N T Cooke, R. H. T. Edwards et al. · Thorax · 1984 · 675 citations · Full text
Medicine, Pediatrics, Physiology +11
International Consensus Report on Diagnosis and Treatment of Asthma.
A L Sheffer, Jean Bousquet, WW Busse et al. · PubMed · 1992 · 674 citations