Acta Orthopaedica · 2011 · 33 citations · 17 references
MedicineOrthopaedic SurgerySurgeryBiomedical ImagingHistopathologyOrthopedicsBone InfectionsJoint InfectionsOrthopedic ImagingOrthopedic InfectionPositron Emission TomographyProsthetic Joint InfectionAseptic Loosening AssessmentFluoride Positron Emission TomographyIntraoperative Tissue SamplingPeriprosthetic Infection DetectionPeriprosthetic Joint Infection DetectionPositron Emission Tomography DetectionSeptic LooseningSurgical Site Infection Detection
BACKGROUND AND PURPOSE: The accurate diagnosis of periprosthetic infection requires assessment of intraoperative tissues. These must be sampled from the appropriate sites. We used (18)F-fluoride positron emission tomography (PET) to identify sites of inflammation in order to improve the sensitivity of histopathology, microbiological culture, and real-time PCR in total hip arthroplasty (THA) patients. PATIENTS AND METHODS: 23 THA patients (23 hips) scheduled for revision surgery (the revision group) and 17 uninfected THA patients (23 hips; control group) were enrolled. Uptake was classified into major, minor, and no uptake. To evaluate the association between the (18)F-fluoride uptake and intraoperative tissue results in the revision group, we calculated their sensitivity on each of the major, minor, and no-uptake sides. RESULTS: 17 revision patients showed major uptake and all were diagnosed as having septic loosening from intraoperative tissue results. Minor uptake was observed in the other 6 revision patients and all were diagnosed as having aseptic loosening. Apart from 3 cases that showed minor uptake regions, control subjects showed no uptake. In the revision group, the sensitivities of histopathology, microbiological culture, real-time PCR separately and also in combination were 0.78, 0.58, 0.96, and 0.96, respectively, on the major (18)F-fluoride uptake sides, 0.0, 0.0, 0.1, and 0.1 on the minor-uptake sides, and 0, 0, 0.18, and 0.18 on the no-uptake sides. INTERPRETATION: Our findings suggest that preoperative assessment of major uptake of (18)F-fluoride markedly improves the accuracy of tissue sampling, and thus the sensitivity of subsequent tissue examinations. More definitive diagnosis of periprosthetic infection is therefore possible.
17
Katrin D. M. Stumpe, Hubert P. Nötzli, Marco Zanetti et al. · Radiology · 2004 · 199 citations
Radionuclide imaging of the painful hip arthroplasty
Patrick Reinartz, T. Mumme, B. Hermanns et al. · Journal of Bone and Joint Surgery - British Volume · 2005 · 162 citations · Full text