Can an Anesthesia Machine Flush Valve Provide for Effective Jet Ventilation?

Sheila D. Gaughan, Jonathan L. Benumof, George T. Ozaki

Anesthesia & Analgesia · 1993 · 42 citations · 0 references

Concepts

Abstract

Transtracheal jet ventilation (TTJV) using a percutane-ously inserted intravenous (IV) catheter for the patient who cannot be ventilated or tracheally intubated or, using a jet stylet for changing endotracheal tubes (Em) in patients for whom subsequent ventilation and/or tracheal reintubation may be difficult, are extremely valuable therapeutic options. The jet ventilation system must have a sufficiently high pressure-oxygen source to drive oxygen through noncompliant tubing and through relatively small IV catheters and/or jet stylets in order to achieve adequate ventilation and oxygenation. There is no evidence that using the common gas outlet of an anesthesia machine by. activating the flush valve can provide enough flow (V̇) and tidal volume (VT) for effective jet ventilation. This in vitro study utilized a mechanical lung model that had a varying lung compliance [Cset (10–100 mL/cm H20)] to determine the VT (measured by integrating a pneumotachograph flow signal) and corresponding minute ventilation (VE) through 14-, 16-, and 18-gauge IV catheters and small, medium, and large jet stylets. The flow of O2 was generated by activating the flush valve of Dráger Narkomed 2 and 2A and Ohmeda Modulus II and II Plus anesthesia machines at an inspiratory: expiratory (1:E) ratio = 1:1 (unit of time = 1 s). We found that the largest VT and resultant V̇E were consistently obtained by activating the flush valve of the Ohmeda Modulus II and Dráger Narkomed 2 anesthesia machines. The smallest VT and V̇E were produced using the Ohmeda Modulus II Plus anesthesia machine. The large differences in V, VT, and V̇E generated by each of the anesthesia machines are due to, and are explained by, the internal construction of the flush valve unique to each of these machines. A one-way outlet check valve is positioned between the vaporizers and flush valve in the Ohmeda Modulus II and Dráger Narkomed 2 anesthesia machines which directs the entire flow of oxygen (45–75 L/min at approximately 50 psi) out the common gas outlet when the flush valve is activated. There is no such valve in the Ohmeda Modulus II Plus or Dráger Narkomed 2A anesthesia machines, so that activating the flush valves directs oxygen toward both the vaporizers and the common gas outlet. Each of these anesthesia machines has a pressure-limiting mechanism so that the pressure out of the common gas outlet of both anesthesia machines is only 7 and 18 psi, respectively, resulting in dramatically lower VT and subsequent V̇E. In conclusion, the Ohmeda Modulus II Plus anesthesia machine is not an acceptable power source for providing total ventilatory support by activating the flush valve for jet ventilation, although the Dráger Narkomed 2, 2A, and Ohmeda Modulus II anesthesia machines are all acceptable power sources for jet ventilation for providing partial, if not total, ventilatory support in most clinical situations. (Anesth Analg 1993;76:800–808)