Publication | Closed Access
Healing of implants installed in over‐ or under‐prepared sites – An experimental study in dogs
30
Citations
23
References
2014
Year
Similar amounts of osseointegration were obtained irrespective of the insertion torque applied. Moreover, implants installed in sites with close to 0 Ncm insertion torque may properly osseointegrate as well.