European Journal of Cardio-Thoracic Surgery · 2009 · 23 citations · 16 references
MedicineSurgeryCardiothoracic SurgeryMedical RoboticsSurgical InstrumentationMinimally Invasive Cardiothoracic SurgeryMinimally Invasive SurgerySuturing InstrumentsAutomated Suturing DevicesBraided SuturesKnot-tying InstrumentsKnot-tying TechniqueMinimally Invasive Surgical TherapyMinimally Invasive Suturing DevicesSurgical Knot TyingSuture-based Fixation
OBJECTIVE: Intracorporeal suturing and knot tying can complicate, prolong or preclude minimally invasive surgical procedures, reducing their advantages over conventional approaches. An automated knot-tying device has been developed to speed suture fixation during minimally invasive cardiac surgery while retaining the desirable characteristics of conventional hand-tied surgeon's knots: holding strength and visual and haptic feedback. A rotating slotted disc (at the instrument's distal end) automates overhand throws, thereby eliminating the need to manually pass one suture end through a loop in the opposing end. The electronic actuation of this disc produces left or right overhand knots as desired by the operator. METHODS: To evaluate the effectiveness of this technology, seven surgeons with varying laparoscopic experience tied knots within a simulated minimally invasive setting, using both the automated knot-tying tool and conventional laparoscopic tools. Suture types were 2/0 braided and 4/0 monofilament. RESULTS: Mean knot-tying times were 246+/-116 s and 102+/-46 s for conventional and automated methods, respectively, showing an average 56% reduction in time per surgeon (p=0.003, paired t-test). The peak holding strength of each knot (the force required to break the suture or loosen the knot) was measured using tensile-testing equipment. These peak holding strengths were normalised by the ultimate tensile strength of each suture type (57.5 N and 22.1N for 2/0 braided and 4/0 monofilament, respectively). Mean normalised holding strengths for all knots were 68.2% and 71.8% of ultimate tensile strength for conventional and automated methods, respectively (p=0.914, paired t-test). CONCLUSIONS: Experimental data reveal that the automated suturing device has great potential for advancing minimally invasive surgery: it significantly reduced knot-tying times while providing equivalent or greater holding strength than conventionally tied knots.
16
Adverse Cerebral Outcomes after Coronary Bypass Surgery
Gary W. Roach, Marc S. Kanchuger, Christina Mora Mangano et al. · New England Journal of Medicine · 1996 · 1.9K citations · Full text
New laparoscopic suturing device: Initial clinical experience
J. B. Adams, Peter G. Schulam, Robert G. Moore et al. · Urology · 1995 · 88 citations
Nursing, Surgery, General Surgery +10
Mitral valve repair robotic versus sternotomy☆
Thierry Folliguet, Fabrice Vanhuyse, X CONSTANTINO et al. · European Journal of Cardio-Thoracic Surgery · 2006 · 87 citations · Full text
Medicine, Cardiology, Surgery +11