Catheterization and Cardiovascular Interventions · 2003 · 158 citations · 5 references
MedicineCardiologySurgeryCardiothoracic SurgeryInterventional CardiologySurgical InstrumentationDevice SafetySeptal DefectsDevice EmbolizationDevice Orientation AssessmentLong-term Cardiac Follow-upPercutaneous Closure DevicesPerimembranous Ventricular Septal DefectTranscatheter Closure DevicesTranscatheter Septal Defect ClosureVentricular Septal Defect Closure
Transcatheter closure of perimembranous ventricular septal defects with coils or devices designed to close other lesions may be complicated by embolization or aortic insufficiency. A new asymmetric Amplatzer perimembranous ventricular septal occluder and delivery system was specifically designed for perimembranous defects. This report describes the first use of this device in 27 patients. Implantation was successful in 25 (93%), with 1 removed for device-related aortic insufficiency and inability to position the delivery sheath in another. Device orientation was excellent when the device was initially advanced through a standard delivery sheath positioned in the left ventricular apex. Twenty-three had complete occlusion within 1 week (92%), with a tiny (< 2 mm) residual shunt in the other two. In the 25 subjects with the device left in place, device-related aortic or tricuspid insufficiency, arrhythmias, and embolization were not observed. These excellent acute results need to be confirmed by long-term follow-up.
5
Transcatheter closure of ventricular septal defects.
James E. Lock, Peter C. Block, Raymond G. McKay et al. · Circulation · 1988 · 534 citations
Medicine, Cardiology, Surgery +17