The Laryngoscope · 2000 · 36 citations · 18 references
MedicineOtolaryngologyRadiologyDiagnostic ImagingDiagnostic RadiologyInterventional RadiologyImage-guided Neck SurgeryMagnetic Resonance ImagingNeck AnatomyNeck ImagingSkull Base ImagingBiopsy Needle PlacementImage-based Biopsy GuidanceImage-guided Fine-needle AspirationImage-guided Neck BiopsyMagnetic Resonance Imaging-guided BiopsyMagnetic Resonance-guided BiopsyNeck Magnetic Resonance ImagingNeedle Guidance
OBJECTIVE/HYPOTHESIS: To test the hypotheses that 1) magnetic resonance imaging (MRI)-guided biopsy and aspiration with an open 0.2-T system (Magnetom Open, Siemens, Erlangen, Germany) in the head and neck is feasible and successful and 2) procedure times can be sufficiently short to be well tolerated by the patient. METHODS: Sixty-one MRI-guided procedures were performed in 47 patients (ages, 6 mo-88 y) in the head and neck, including the mucosal sites and masticator and parapharyngeal spaces (n = 23), parotid space (n = 6), submandibular space (n = 2), cervical vertebral column/paraspinal tissues (n = 8), skull base (n = 3), larynx or hypopharynx (n = 3), and infrahyoid nodal chains and surrounding tissues (n = 16). A clinical C-arm imaging system was used, supplemented by an in-room radiofrequency-shielded liquid crystal monitor, rapid gradient echo sequences for needle guidance, and MRI-compatible anesthesia, monitoring, and surgical lighting equipment. Tissue sampling included fine-needle aspiration (n = 58) and cutting-needle core biopsy (n = 27), with 24 patients undergoing both procedures. Procedures were evaluated for success of needle placement, procedure time, and complications. RESULTS: Successful needle placement was accomplished in all cases without complication, with tissue sufficient for pathological diagnosis obtained for all but five patients with an average of 2.1 passes per patient. For fine-needle aspiration, average instrument time was 7.8 minutes per pass, and average cutting-needle core biopsy time was 9.2 minutes. CONCLUSIONS: Interactive MRI guidance for needle biopsy and aspiration of deep head and neck lesions is feasible, successful, and safe. Procedure times are sufficiently short to be well tolerated by the patient.
18
BIOPSY BY NEEDLE PUNCTURE AND ASPIRATION
Hayes Martin, Edward Ellis · Annals of Surgery · 1930 · 787 citations · Full text
Interactive MR-guided biopsy in an open-configuration MR imaging system.
Stuart G. Silverman, B. Collick, Michael R. Figueira et al. · Radiology · 1995 · 328 citations
MR-guided aspiration biopsy: needle design and clinical trials.
Peter R. Müeller, D D Stark, Joseph F. Simeone et al. · Radiology · 1986 · 183 citations