Journal of The Electrochemical Society · 1964 · 44 citations · 0 references
Natural SciencesChemistryMaterials ScienceElectrochemical EngineeringElectrochemistrySurface ScienceElectrochemical CellsElectrode KineticsElectrode MaterialsElectrode PotentialsRedox-active MaterialsWorking ElectrodesElectrochemical Equilibrium PotentialElectrochemical ReversibilityElectrode Potential MeasurementGold ElectrodesNernst EquationOxygen Partial Pressure EffectsPlatinum ElectrodesTafel Analysis
The reversible oxygen electrode has been set up on anodized plat inum in ultrapure sulfuric acid solutions. The essential conditions for establishing the reversible oxygen electrode are described. It is found that the variation of the electrode potential with partial pressure follows the theoretical expression. At other stable potentials exhibited by the plat inum oxygen system the partial pressure effects give variations not consistent with any theoretical formula. Decay curves on open circuit have been measured and a dependence on the oxygen partial pressure has been observed. In ultrapure solutions the poten-tial decays after several hours to a l imiting value of 1.1v corresponding to the Pt-PtO2-Pt(OH)2 potential. When the solutions are impure the limit is low-ered to about 0.84v which is the equil ibrium potential of the P tOH-OH- hy-drogen peroxide system. The gold-oxygen system also exhibits a number of different oxide potentials, one of these is at 1.23v in normal acid solution. The apparent establishment of the reversible oxygen electrode potential on gold