Concepedia

Publication | Closed Access

An iterative approach to the analysis of EM autoradiographs

25

Citations

13

References

1978

Year

Abstract

An iterative scheme is described for determing the most appropriate "model" for dividing micrographs of EM autoradiographs into identified items of known relative specific activities in such a way that the dispersion of silver grains over the autoradiographs is fully and satisfactorily explained. A trial model is first set up for which, using a square matrix of estimates of notional cross-fire between the chosen items, a "solution" is obtained. The quality of the model is then tested using extended cross-fire data contained in rectangular matrix. If the model is shown to be unsatisfactory, an improved model (of tissue subdivision) is postulated and the whole process repeated until the model is deemed to be satisfactory. The computations are such that the data can be processed rapidly on the laboratory bench using a small machine. The logical estimation of errors is facilitated by this approach.

References

YearCitations

1969

427

1966

325

1969

289

1977

171

1978

131

1965

118

1977

108

1973

94

1971

84

1970

71

Page 1